| Transducers |
|
|
|
|
|
|
| Type |
3.5C60 |
5.0C40 |
3.5C13 |
5.0C13 |
6.5C13 |
6.5CV13 |
5.0LR64 |
5.0L64 |
7.5L64 |
7.5L40 |
| Specification
|
| Scanning
method |
Electronic
Convex
|
Electronic
Liner |
| Frequency
(MHz) |
3.5 |
5.0 |
3.5 |
5.0 |
6.5 |
6.5 |
5.0 |
5.0 |
7.5 |
7.5 |
| Width/angle |
63o |
80o |
137o |
137o |
137o |
64mm |
64mm |
64mm |
40mm |
Applications |
| Abdominal |
|
|
|
|
|
|
|
|
|
|
| Smal
Parts |
|
|
|
|
|
|
|
|
|
|
| Vescular |
|
|
|
|
|
|
|
|
|
|
| Obsterics |
|
|
|
|
|
|
|
|
|
|
| Gynecology |
|
|
|
|
|
|
|
|
|
|
| Pediatrics |
|
|
|
|
|
|
|
|
|
|
| Neonatology |
|
|
|
|
|
|
|
|
|
|
| Urology |
|
|
|
|
|
|
|
|
|
|
| Cardiology |
|
|
|
|
|
|
|
|
|
|
| Endocavity |
|
|
|
|
|
|
|
|
|
|
| Biopsy |
|
|
|
|
|
|
|
|
|
|
| |
Main
Application |
|
Alternative
Application |
|
Option
Kit Application |
| Technical
Specification |
|
| Scanning
Methods |
Reports |
|
Electronic Convex
Eletronmic Microconvex
Electronic Linear |
OB and Cardiac |
| Display
Mode |
Display
Annotations |
|
B, B/B, M, B/M |
Hospital ID, Patient ID, date, Hour, Transducer,
Zoom, Focus, Text |
| Gain
Control |
Transducer
Port |
|
6 Slide potentiometers with display of gain curve
on screen |
1 (DMS-EXPLORER)
2 (DMS -EXPLORER PLUS) |
| Magnification |
Presets |
X1.1,X1.2, X1.3, X1.6, X1.9, X 1 with scrolling
|
6 user programmable configurations |
| Focusing
mathod |
Viewing
Monitor |
|
16 steps electronic multifocus in transmission
Dynamic focus in reception |
9" diagonal |
| Grayscale |
Video
Output |
|
256 levels |
Composed Video Signal 75 Ohm
Optional SVGA
Optional Digital Video |
| Image
Memory |
Interface
|
2 images
Optional Flash Memory up to 64 Images |
RS-232 port |
| Pre
& PostProcessing |
Digital
output |
Gamma Corrrection
Edge Definition
Frame Average
Horizontal Inversion
Vertical Inversion
Negative/Positive |
Optional ImageScan ( parallel or USB)
Power Supply
90~240 VAC, 50/60 Hz 50 VA
Dimensions
445x300x280 mm, 11 kg |
Measuring
Funcation
B-Mode |
Standards |
Distance
(4)
Circumference(2)
Area (2)
Ellipsce, Volume, Angle |
IEC
601-1+A1+A2
EN 60601-1-1:1993
EN 55011:1998 |
| M-Mode |
Options |
Distance
(2)
Time (2) Slope (2)
|
Flash
memory
Battery Power System
Footswitch
3D reconstruction
I mageScan
Video Printer
External monitor |
| Biopsy
Guide |
|
| Vaginal
and rectal Probe |
|
Calculating
Finctions
Obstreics |
|
| GSD,
CRL, BPD, HC, FL, TBD, APBD, AC, EDD, FW, HC/AC,
FL/AC |
|
| Cardiac |
|
LV,MVCF, IT/ET, BSA, LA, HR, MV, MW, MI
|
|
|
|
|
All
Right Reserved by Danatech Medical Systems, Inc, ©2005-2006.
14930 SW 104 St #26, Miami FL 33196, USA Ph: 305.388.2831 Fax: 305.883.9418
|
|
|